The RAPIDPoint 500e System elevates Siemens Healthineers blood gas offering to a new level, allowing you to spend more time focused on patient care. Implement a proven end-to-end blood gas solution that reduces the daily burden of device management and enables you to give your full care and attention where it matters most.
With an improved user experience, the analyzer transforms care delivery, setting an elevated standard in simplicity, quality assurance, and data security for healthcare organizations
Parameters |
Analyte |
Blood Gas |
pH, pCO2 and pO2 |
Electrolytes |
Na+, K+, Ca++ and CI– |
Metabolites |
Glucose and Lactate |
CO-oximetry |
tHb, sO2, O2Hb, HHb, COHb, MetHb and Neonatal Total Bilirubin |
The RAPIDPoint 500e system also supports additional sample types: pleural fluid pH; Na+, K+, Ca++, Cl–, pH, pCO2, and HCO–3(act)† for dialysate fluid‡ samples.
†pH, pCO2, and HCO–3(act) are provided for reference only.
Sample volume |
100 µL |
Analysis |
Time to results is approximately 60 seconds |
Quality Control |
Automatic QC or ampule QC
Three levels of independent quality control solutions Customizable QC schedule |
Measurement Cartridge |
Cartridge initialization time is approximately 24 minutes |
Use life |
28 days onboard, or maximum number of tests
|
Integrated Barcode Scanner |
1D barcode symbologies – Code 128, Codabar, Code 39, Character/Digit, Interleaved 2 of 5 2D barcode symbologies – PDF417, MicroPDF417, Datamatrix, QR Code, Micro QR Code, Aztec, and Maxicode |
Operating System |
MICROSOFT WINDOWS 10 IoT
|
Communications | LIS Wireless Dual-port transmission via Ethernet and serial port POCcelerator™ Data Management System POCcelerator SE Data Management System |
Healthcare professionals are increasingly under pressure to deliver quality care in busy critical care settings. Any delay, distraction, or concern in the generation and reporting of test results physicians rely on can add to the operational burden and take time and focus away from the patient.
To give you confidence in every result while reducing the time to diagnosis and treatment, the RAPIDPoint 500e system provides robust accuracy from sample to sample by leveraging the Siemens Healthineers-designed Integri-sense™ Technology—the guardian of patient results. Integri-sense Technology is a comprehensive series of analyzer functional checks and flagging mechanisms designed to deliver accurate test results. It performs frequent quality and blood integrity checks before, during, and after every patient sample. Three levels of independent automatic quality control, multiple calibration routines, and advanced software algorithms combine to enable the RAPIDPoint 500e analyzer to be ready to generate reliable and clinically actionable test results each and every time.
Depend on the RAPIDPoint 500e system to raise the bar in blood gas IT security at your facility with the latest defenses to guard confidential patient data coupled with the leading built-in technology to protect your institution from external cybersecurity threats. The WINDOWS 10 operating system has been equipped with McAfee embedded anti-malware, which blocks unknown and unauthorized programs from running. Other key security advantages include a two-step authentication process, an encrypted password requirement for patient data transfer, and the inclusion of a firewall to block hacking attempts.
This user-friendly and maintenance-free analyzer provides the patient results most needed by clinicians in critical care environments. The simplicity of the RAPIDPoint 500e system centers on the fact that it is a fully cartridge-based analyzer, with no maintenance required. The measurement cartridge includes the planar sensors, sample probe, and CO-ox chamber, so all these components are replaced with every new cartridge.
One of the unique features of the RAPIDPoint 500e system is the sample port. Syringe and capillary samples are handled in exactly the same way, and operator variability is eliminated with hands-free automatic sampling. Only 100 µL of sample is aspirated, and the sample port is part of the advanced clot management and air bubble detection mechanism.
Integri-sense Technology is the guardian of patient results. The system performs frequent quality and sample integrity checks before, during, and after every patient sample. Automatic quality control, comprehensive calibrations, and advanced software algorithms combine to enable the analyzer to be ready to generate reliable, clinically actionable results each and every time, delivering confidence with every result.
Service is essential to keep medical equipment operational and safe. Our Nordic service team consists of experienced service technicians stationed across the Nordic countries. Our service technicians are ready to take on your every service need.”
IncuCap® – Innovative incubator cover made of a High-Tex material
IncuCap® is made of a 3-layered functional specialty knit fabric. A highly elastic, breathable membrane in the core assures the incubator cover’s imperviousness to light. The 3D knit spacing fabric underneath ensures optimum noise attenuation, provides an anti-slip effect, and permanently retains the cover’s shape. Additionally, the material is characterized by low weight.
IncuCap® has been tested and certified according to Oeko-Tex® Standard 100, is bi-elastic, breathable, washable up to 95 °C and suitable for tumble-drying. The anti-slip (silicone) interior lining is neutral so that the child can be evaluated without any interfering influences. Access to the infant is flexible and ensured by 4 side and 2 head/foot flaps. Optionally available with an opening flap for phototherapy lamps, including magnetic openings as an option.
BiliSwaddler®, phototherapy with fiberoptic lightpads
BiliSwaddler alows you to practise development-promoting care practically anywhere, whenever it is in the newborn intensive care unit, nursery or at home. During the therapy session, the baby can be breast fed or held without it impairing on the bonding between the infant and parents. One Swaddler size for all commonly used phototherapy fiber optic pads such as GE Healthcare, Natus Medical, Atom Medical etc.
Soft cushioning (3D knit fabric) for pressure relief and support of moisture management for optimum climatic control. BiliSwaddler can be used in a baby bed or in the arms of a caregiver (kangaroo care). Innovative Interlock-fabric (80% CO, 20% PES Trevira bioactive®) with a permananet antimicrobial effect is gentle and prevents skin irritation. Please use appropriate eye-protection during photo therapy sessions.
Phototherapy positioning aid
Effectiveness – combined with security and stability with our Bilitex positioning aid specifically developed for phototherapy. The little patients are prone to stretch patterns and nervous movements, particularly during therapeutic phases. This is due to lack of muscle tone and the unbounded surroundings, which cost a lot of energy. With the Bilitex positioning aid, the preemie experiences a secure and flexible environment during therapy, which allows the infant to adopt a relaxing position.
The innovative textile material features a special mesh structure with 85% permeability to the high-intensity radiation spectrum. In addition, the knit fabric is very soft and breathable – the desired size can be individually adjusted using a flexible closure (Velcro®). The product is developed in cooperation with the University Hospital in Tubingen. It is tested and certified according to Oeko-Tex®Standard 100.
An accurate and reliable activity monitor
The wGT3X- BT is Actigraph’s flagship model. Scientific communities around the globe use the wGT3X- BT for several reasons, including its ability to gather activity data with accuracy and ease. The activity monitor is Bluetooth® compatible and features light sensors, making it optimal for both activity and sleep monitoring. The Actilife software provides accurate and updated analysis for all areas of use. When scientists or researchers publish new analysis algorithms, Actilife is updated in order to make sure that the wGT3X- BT always has the latest and best tools you could ask for.
USP:
Timik ApS
Sivlandvænget 27B, st. th.
5260 Odense S
Tel: +45 8230 6700
Org.nr 36089210